Description
4 pole mini circuit breaker (MCB) with a rated current of 10 amp is ideal for use in low voltage distribution systems. This miniature circuit breaker features a short circuit breaking capacity of 6 kA at 230/400V AC, ensuring that the breaker can quickly and effectively interrupt high fault currents, preventing potential fire hazards, equipment damage, and system failures.
4 Pole MCB Breaker Information
- Rated Current: 10 amp
- Rated Voltage: 230/400V AC, 50Hz
- Number of poles: 4 pole
- 6 kA rated short-circuit breaking capacity
- Compliant with IEC standard
- C curve trip characteristic
- With overload protection and short circuit protection function
Technical Data
| Model | ATO-NB8-634PC10 | |
| Rated Current | 10A | |
| Rated Voltage | 230/400V | |
| Frequency | 50Hz | |
| Number of Poles | 4P | |
| Mechanical Life | 20000 Times | |
| Electrical Life | 10000 Times | |
| Rated Short-Circuit Breaking Capacity | 6000A | |
| Operating Short-Circuit Breaking Capacity | 6000A | |
| Rated Impulse Withstand Voltage (1.2/50) | 6kV | |
| Dielectric Test Voltage | 2000V (50Hz, 1 min) | |
| Heat & Humidity Resistance | 28 Cycles | |
| Vibration Resistance | No Obvious Vibration and Impact | |
| Terminal Block | Terminal Block Type | Pillar Terminal Block |
| Min. Terminal Size Acceptability | 1mm2 | |
| Max. Terminal Size Acceptability | 25mm2 | |
| Standard Connection Torque | 2 N.m | |
| Max. Tolerable Torque | 2.5 N.m | |
| Wire Insertion Depth | 13mm | |
| Reference Temperature | 30℃ | |
| Operating Temperature | -35℃~+70℃ | |
| Storage Temperature | 35℃~+85℃ | |
| Applicable Altitude | 2000m | |
| Tripping Mode | Thermal Magnetic Trip | |
| Electromagnetic Tripping Type | Type C (5In-10In) | |
| Shell Flame Retardant Grade | V0 | |
| Wire Entry Method | Both Upper and Lower | |
| Installation Method | TH35-7.5 Standard Rail | |
| Protection Level | Direct Installation | IP20B |
| Installed in the Distribution Box | IP40B |
4 Pole MCB Breaker Dimensions (Unit: mm)
Details
Tips: Common faults and solutions of miniature circuit breaker
Miniature Circuit Breakers (MCBs) are commonly used for protecting electrical circuits. Here are some common faults and their solutions:
Tripping without Load
- Cause: Mini circuit breaker may be faulty or worn out, or it could be due to an internal fault like insulation damage.
- Solution: Replace the MCB with a new one. Ensure no underlying circuit faults are causing the trip.
Frequent Tripping
- Cause: Overloading, short circuits, or earth faults.
- Solution: Check for overloaded circuits, and verify wiring for short circuits or grounding issues.
MCB Doesn’t Trip on Overload
- Cause: The MCB’s thermal element could be defective.
- Solution: Replace the faulty MCB.
Physical Damage
- Cause: External impact or deterioration over time.
- Solution: Replace the damaged MCB to prevent safety risks.
Failure to Reset
- Cause: Mechanical failure or internal fault.
- Solution: Inspect the micro circuit breaker and replace it if necessary.