Description
Affordable price 3 hp (2.2 kW) VFD, features 220v/ 230v /240v single phase input, 380v three phase output. This frequency drive inverter built-in RS485 communication interface, easy to wire and operate.
Specification:
| Basics | Model | GK3000-CS0022 |
| Capacity | 3 hp (2.2 kW) | |
| Shipping weight | 5 kg | |
| Dimension | 272*172*182 mm | |
| Installation size | 256*155 mm | |
| I/O Feature | Rated current | 5.1 A |
| Input voltage | 1 phase 220~240V AC | |
| Input frequency | 50Hz/ 60Hz | |
| Output voltage (Optional) | 3 phase AC 380V/ 400V/ 415V/ 440V/ 460V (Note: 440V, 460V output voltage only for the 1-phase 240V input VFD) | |
| Output frequency | 0Hz~1000Hz | |
| Over load capacity | 150% of rated current for 1 minute, 180% of rated current for 3 seconds | |
| Control Feature | Control mode | V/F control; Sensorless vector control; |
| Communication | RS485 | |
| Speed regulation | 1:100 | |
| Start torque | 150% of rating torque at 1 Hz | |
| Speed control accuracy | ≤±0.5% of rating synchronous speed | |
| Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% |
|
| Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz |
|
| Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
| Interior PID controller | Be convenient to make closed-loop system | |
| Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
| Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
| Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
| Environment | Enclosure rating | IP 20 |
| Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% | |
| Humidity | 5%-95%, without condensation | |
| Altitude | ≤1000m; VFD will be derated if above 1000m | |
| Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) | |
| Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
5 tips for using 1-phase 220V to 3-phase 380V VFD
- The power at the input of the variable frequency drive must be sufficient, otherwise the operation will jump under voltage fault can not be normal operation.
- Single phase 220v to three phase 380v VFD belongs to the boost circuit step-up, for the load side of the maximum for the light-load site below 30hp (22kW), in terms of selection, the light-load motor use a large level of VFD, heavy-load site use a large two-level VFD.
- 1-phase to 3-phase VFD can only be used for motor class inductive load, can not be used as other load power supply.
- The VFD is not suitable for the need to quickly start and stop the site, and the occasion of the bit energy load.
- Part of the equipment motor can be used by changing the motor connection three-phase 220V electricity (such as motor star connection state is three-phase 380V motor, can be changed to delta connection can use three-phase 220V, the specific can consult the motor manufacturer), at this time can buy ATO single-phase 220V to three-phase 220V VFD to solve the problem of phase change.