Sale!

20kVA 440V to 120V/240V Split Phase Transformer

Original price was: $2,979.00.Current price is: $298.98.

🚚 Free Shipping Over $60!

⚡ Fast Shipping

🔒 Secure Payment

⭐ Trusted Quality

💬 Friendly Customer Support

📦 Fast Nationwide Delivery

SKU: ATO-T-DGS20kVA Category:

Description

20kVA single phase to split phase transformer with wheels, frequency 50/60Hz, step down 440V input voltage to 120V/240V output voltage, frequency 50/60Hz, work efficiency up to 95%.

20 kVA Single Phase to Split Phase Transformer Specifications

Model ATO-DGS20kVA
Phase Single phase to split phase
Capacity 20 kVA
Primary Voltage 1 Phase / 2 phase 110, 120, 208, 220, 230, 240, 380, 415, 440, 460, 480,
Secondary Voltage 120V/240V AC(L1, L2, N, L+L=240V, L+N=120V)
Frequency 50/60Hz
Winding Material Aluminum/Copper wire (Optional)
Work Efficiency ≥95%
Insulation Resistance ≥50 MΩ
Electrical Strength 2000V AC/1 min
Noise ≤35dB (1 meter)
Insulation Grade Grade B (130℃), Grade F (155℃), Grade H (180℃)
Cooling Method Natural or air cooling
Overload Capacity Allow more than 1.2 times rated load to work for up to 1 hour
Induced Overvoltage Withstand Test 125Hz/800V/min
Transformation Ratio <3%
Air Carrying Current <6%
Impedance Voltage About 6%
Total Losses 10%
Certification CE, ISO
Temperature -15℃~+45℃
Humidity ≤90%RH, without condensation
Altitude <2000m, non corrosive gas and conductive dust
Enclosure Protection Grade IP20
Warranty 12 months
Weight of Aluminium Wire Transformer Open type: 145kg
Protected type: 180kg
Weight of Copper Wire Transformer Open type: 150kg
Protected type: 185kg

20 kVA Single Phase to Split Phase Transformer Schematic Diagram

20 kVA Single Phase to Split Transformer Dimension (Unit: mm)

Aluminium Wire Transformer Size Copper Wire Transformer Size
Open type: a*b*c=370*380*520mm Open type: a*b*c=330*340*470mm
Mouting size: D*E=190*220mm (aperture: 20*10mm) Mouting size: 280*185mm (aperture: 20*10mm)
Protected type: A*B*C=455*660*710mm Protected type: A*B*C=420*610*610mm

Details

Tips: The difference between no-load and load transformer

The main difference between no-load operation and load operation of the transformer is mainly reflected in the secondary line state. The secondary line of the transformer load operation is connected to the load, and the generated power is large.

The transformer uses the principle of electromagnetic induction to change the AC voltage. The main components are the primary coil, the secondary coil and the iron core (magnetic core). In electrical equipment and wireless circuits, it is often used for voltage rise and fall, impedance matching, and safety isolation. When the transformer is running at no load; only no-load loss, that is, iron loss and stray, is consumed, which is 6% of the total capacity, and when the load is running, it is no-load loss + load loss, that is, copper loss, which is the total consumption of the transformer.

Reviews

There are no reviews yet.

Be the first to review “20kVA 440V to 120V/240V Split Phase Transformer”

Your email address will not be published. Required fields are marked *