Description
Single acting piston pump with simple structure, nominal flow rate of 160L/min at 1000r/min, nominal flow rate of 240L/min at 1000r/min, inlet and outlet diameter and connection and system matching, easy installation and disassembly.
Specification
- Model: ATO-PP-160YCY
- Max Drive Power: 125 hp (94.5 kW)
- Driving Method: Hydraulic
- Theoretic Flow: 1000rpm (160L), 1500rpm (240L)
- Number of Impellers: Single stage
- Pump Shaft Position: Horizontal
- Nominal Displacement: 160 cc/rev
- Nominal pressure: 31.5 Mpa
- Material: Cast iron
- Weight: 160 kg
- Warranty: 12 Months
125 hp Single Acting Axial Piston Pump Dimension (unit: mm)
| B | b | bo (N9) | b1 | b2 | b3 | D0 | D1 (f9) | D2 | D3 | d (h6) | d1 | d3 |
| 329 | 340 | 16 | 100 | 120 | 90 | 198 | 150 | 240 | 300 | 55 | 52 | M22 x 1.5 |
| h1 | h3 | L | I | I0 | I1 | I2 | I3 | I4 | I5 | t | d0 x h0 |
| 141 | 25 | 525 | 106 | 100 | 4 | 110 | 180 | 230 | 411 | 59 | M16 x 35 |
Axial Piston Pump Detail
Tips: What should be noted when using the oil pump?
- The inlet and outlet of the oil pump must be fitted with a combination of gaskets and a layer of grease on the outside of the pipe joint after it is connected to prevent air from entering.
- Be sure to fill the oil return hole before use, otherwise the oil pump will be short of oil and instant wear.
- After injecting oil and connecting all the pipes, it should be idle for 10 minutes and then start to play pressure, so that the residual air in the pump and pipes can be discharged.
- The oil pump’s oil inlet can not be installed with a screen or filter, which will cause damage to the oil pump due to insufficient oil suction. The filter can be installed in the oil tank or in the oil outlet.