Description
Step down control transformer converts single phase 240V AC to 110/36/24V AC, input/ output voltage can be customized as your requirement. In general, for the 500VA control electric transformer, input rated voltage less than 500V, output rated voltage less than 240V, worked as control power supply for mechanical equipment and general electrical appliance and as power supply for work lighting and signal lamp.
Specifications
| Product Name | Single phase control transformer |
| Product Model | ATOBK-500VA |
| Winding Material* | Enameled copper wire or enameled aluminum wire (Optional) |
| Total Output Capacity | 500VA Note: (If your output includes multiple voltage levels, please email us with the capacity of each output. The total capacity should be the sum of all individual outputs. For example, if your outputs are aV and bV, then aV (capacity) + bV (capacity) = 500VA). |
| Primary Voltage* (VAC) | 110, 120, 208, 220, 230, 240, 380, 400, 480, 110/220, 120/240, 240/480…(Optional and Customized) |
| Secondary Voltage* (VAC) | 6, 12, 24, 36, 48, 110/48, 120/24, 208/36, 220/48, 230/36, 240/120, 120/24/12, 110/36/24, 127/36/6, 208/48/36/24…(Optional and Customized) |
| Frequency | 50 / 60Hz |
| Insulation Level | F / H |
| Withstand Voltage Test | Primary to secondary 2.5KV/min |
| Primary to safety ground 2.5KV/min | |
| Secondary to safety ground 1.5KV/min | |
| Insulation Resistance | Primary to secondary 2500V>100 megohm |
| Primary to safety ground 2500V>100 megohm | |
| Secondary to safety ground 1500V>100 megohm | |
| Induction Withstand Voltage Test | 125Hz/ 800V/min |
| Ground Resistance | 25A<80 milliohm |
| Cooling Method | Natural or air cooling |
| Transformation Ratio | <3% |
| Air Carrying Current | <6% |
| Impedance Voltage | about 6% |
| Total Losses | 0.1 |
| Efficiency | 80%~99% |
| Operating Temperature | -25℃~40℃ (40℃, 93% RH, 56 days) |
| Storage Temperature | -25℃~100℃ (40℃, 93% RH, 56 days) |
| Certificate | CE, ISO |
| Warranty | 12 months |
| Size | Overall size: 132*135*140mm, Hold distance for installation: 100*105mm, Installation hold: 12*7mm |
| Weight | 10kg |
Schematic diagram illustration
Control transformer dimension
| Overall size (mm) | Hole distance for installation (mm) | Installation hole (mm) | |||
| B | E | D | A | C | K x J |
| 132 | 135 | 140 | 100 | 105 | 12 x 7 |
Tips: ATO 500VA-10kVA control transformers working environment
- Ambient air temperature: -5℃~+40℃, the highest monthly mean temperature should not exceed +30℃.
- Altitude for installing place should not exceed 1000m.
- When the ambient air temperature is +40℃, the relative humidity should not exceed 50%, and it allows higher relative humidity under lower temperature. Max average humidity in the dampest month is 90%, meanwhile the lowest average temperature of this month is +25℃, and condensation on the product surface caused by temperature change should be taken into consideration.





Reviews
There are no reviews yet.