Description
20 amp 3 pole miniature circuit breaker (MCB) is used to electrical circuits from overloads and short circuits. This C20 mini circuit breaker with C curve trip characteristic allows for the protection of all 3 conductors in a 3 phase system, providing circuit protection.
3 Pole MCB Breaker Information
- Rated Current: 20 amp
- Rated Voltage: 230/400V AC, 50Hz
- Number of poles: 3 pole
- 6 kA rated short-circuit breaking capacity
- Compliant with IEC standard
- C curve trip characteristic
- With overload protection and short circuit protection function
Technical Data
| Model | ATO-NB8-633PC20 | |
| Rated Current | 20A | |
| Rated Voltage | 230/400V | |
| Frequency | 50Hz | |
| Number of Poles | 3P | |
| Mechanical Life | 20000 Times | |
| Electrical Life | 10000 Times | |
| Rated Short-Circuit Breaking Capacity | 6000A | |
| Operating Short-Circuit Breaking Capacity | 6000A | |
| Rated Impulse Withstand Voltage (1.2/50) | 6kV | |
| Dielectric Test Voltage | 2000V (50Hz, 1 min) | |
| Heat & Humidity Resistance | 28 Cycles | |
| Vibration Resistance | No Obvious Vibration and Impact | |
| Terminal Block | Terminal Block Type | Pillar Terminal Block |
| Min. Terminal Size Acceptability | 1mm2 | |
| Max. Terminal Size Acceptability | 25mm2 | |
| Standard Connection Torque | 2 N.m | |
| Max. Tolerable Torque | 2.5 N.m | |
| Wire Insertion Depth | 13mm | |
| Reference Temperature | 30℃ | |
| Operating Temperature | -35℃~+70℃ | |
| Storage Temperature | 35℃~+85℃ | |
| Applicable Altitude | 2000m | |
| Tripping Mode | Thermal Magnetic Trip | |
| Electromagnetic Tripping Type | Type C (5In-10In) | |
| Shell Flame Retardant Grade | V0 | |
| Wire Entry Method | Both Upper and Lower | |
| Installation Method | TH35-7.5 Standard Rail | |
| Protection Level | Direct Installation | IP20B |
| Installed in the Distribution Box | IP40B |
3 Pole MCB Breaker Dimensions (Unit: mm)
Details
Tips: How to choose a miniature circuit breaker for the motor?
When selecting a miniature circuit breaker (MCB) for a motor, consider the following key factors:
- Current Rating: Choose a mini MCB breaker with a current rating that matches the motor’s full-load current. It’s important to select a micro circuit breaker that can handle the motor’s startup current, which can be significantly higher than the running current.
- Motor Type and Inrush Current: Motors, especially induction motors, have a high inrush current during startup. Choose a mini MCB with a C curve (for moderate inrush currents) or D curve (for motors with high inrush currents) to avoid unnecessary tripping during startup.
- Breaking Capacity: Ensure the MCB’s short-circuit breaking capacity is sufficient to handle potential fault currents without damage.
- Voltage Rating: Make sure the MCB’s voltage rating matches or exceeds the motor’s operating voltage (typically 230V for single-phase or 400V for three-phase motors).
- Overload Protection: The MCB circuit breaker should provide overload protection based on the motor’s characteristics to prevent damage from prolonged excessive current.