Sale!

Senva TGW-BCN-F Wall Mount Dual Toxic Gas CO/NO2 Sensor/Controller, BACnet MS/TP, Modbus RTU, Modbus ASCII Output, 10k T3 Temperature, LCD Display, Clear/Tinted Enclosure, 7-Year Warranty

Original price was: $562.66.Current price is: $112.53.

🚚 Free Shipping Over $60!

⚡ Fast Shipping

🔒 Secure Payment

⭐ Trusted Quality

💬 Friendly Customer Support

📦 Fast Nationwide Delivery

SKU: TGW-BCN-F Category:

Description

Senva TGW-BCN-F : Wall Mount Dual Toxic Gas CO/NO2 Sensor/Controller, BACnet MS/TP, Modbus RTU, Modbus ASCII Output, 10k T3 Temperature,  LCD Display, Clear/Tinted Enclosure, 7-Year Warranty

Applications

  • Ensure adequate air flow in occupied spaces
  • Ideal fo parking lot garages 
  • Monitor multiple toxic gases with one mounted unit
  • Alert occupants of elevated gas levels
  • Directly control exhaust fans

Specifications

Power Supply 15-30VDC/24VAC(1), 4W max, 160mA max.
BACnet /Modbus  
Protocol RS-485 BACnet MS/TP, Modbus RTU, Modbus ASCII
Baud Rates BACnet MS/TP, Modbus RTU, Modbus ASCII
Fan Relay  
Fan relay characteristics N.C. 1A@24/30VDC (50/60Hz) (no mains connection)
CO fan relay setpoint 25ppm (default), 0-1000 ppm (menu selectable)
NO2 fan relay setpoint 1ppm (default), 0-30ppm (menu selectable)
Alarm Relay  
Alarm relay characteristics N.C. 1A@24/30VDC (50/60Hz) (no mains connection)
CO alarm relay setpoint 100ppm (default), 0-1000 ppm (menu selectable)
NO2 alarm relay setpoint 3ppm (default), 0-30ppm (menu selectable)
Display  
3-1/2 digit LCD Indicates CO ppm, NO2 ppm (menu selectable)
LEDs  
Green, Yellow, Red Green = Normal, Yellow = Warning/Fan Relay, Red = Alarm/Alarm Relay
Audible Alarm Exposure  
85dB Piezo transducer 30 minutes above alarm setpoint per UL2034 (menu selectable)
CO Sensor Performance  
Type Electrochemical
Accuracy ±5% of default range(2) ±5%of reading above 200ppm
Resolution 1ppm
Certifications UL2034 Listed Component
Life expectancy >7 years
Coverage Area 5000-7500 square feet (placed within 50′ apart from a Senva TG sensor)
NO2 Sensor Performance  
Type Electrochemical
Accuracy ±5% of default range(3) ±5%of reading above 20ppm
Resolution 0.1ppm
Life expectancy >7 years
Coverage Area 5000-7500 square feet (placed within 50′ apart from a Senva TG sensor.)
Enclosure (Wall & Duct)  
Material ABS/Polycarbonate
Dimensions 4.0”h x 4.4”w x 2.1”d (+6.8” probe for duct version)
Conduit Opening Tapped 1/2” NPT
Rating IP20
Compliance UL61010-1 Listed UL, cUL, CE

 

Datasheets

Senva TG UL Toxic Gas CO-NO2 Sensor Datasheet
Senva TG UL Install Manual
TG UL Field Calibration Instructions
User’s Guide TG Series
Buy America Act Certification
Engineering Specifications
LADBS Acceptance
Application Note Detecting Toxic Gases
Understanding Cross-Sensitivities
Application Note TG Sensor Placement
TG UL Series BACnet User Manual
New TGD Duct Mount Toxic Gas Sensors

Reviews

There are no reviews yet.

Be the first to review “Senva TGW-BCN-F Wall Mount Dual Toxic Gas CO/NO2 Sensor/Controller, BACnet MS/TP, Modbus RTU, Modbus ASCII Output, 10k T3 Temperature, LCD Display, Clear/Tinted Enclosure, 7-Year Warranty”

Your email address will not be published. Required fields are marked *