5.5 kW AC vfd line reactor, 3 phase input, voltage optional 220V, 380V, 400V, 460V and 480V. It is widely used in various power supply places with a frequency of 50Hz/60 Hz and is worth your choice.

7.5 hp Input Line Reactor Specifications

Basic Model ATO-ACR-0015-0M94-0.4SC
Recommended VFD Model GK3000-4T0055G (7.5 hp three phase VFD)
Phase 3 Phase
Power 7.5 hp (5.5 kW)
Weight 3 kg
Technical Parameters Work Voltage 380V (optional: 220V/ 240V/ 400V/ 415V/ 440V/ 460V/ 480V)
Work Frequency 50Hz/60 Hz
Rated Current 15 A
Max Current 1.5 Times the Rated Current, Continued 60s
Inductance Value 0.94 mH
Material Aluminium/Copper (Optional)
Voltage Drop 2%
Noise ≤65dB
Insulation Class Class F, H
Protection Class IP00-IP22
Insulation Resistor ≥100MΩ
Working Environment Operation Environment -10℃~+45℃
Temperature Rise ≤85K
Humidity ≤90%RH, without condensation
Running Ambient Temperature -25℃~+45℃
Altitude ≤2000m

7.5 hp Input Line Reactor Size & Circuit Diagram


Dimension (±5mm)
L D W W1 H A×B
115mm 90mm 95mm 68mm 135mm 6×11

Tips:

Reactors have a variety of functions to improve the reactive power, including:

  • Capacitance effect on light airborne or lightly loaded lines to reduce power frequency transient overvoltage.
  • Improve the voltage distribution on long-distance transmission lines.
  • Make the reactive power in the line as light as possible on the light load, prevent the irrational flow of reactive power and reduce the power loss on the line.
  • When the large unit is in parallel with the system, reduce the steady-state voltage of the power frequency on the high-voltage bus, so that the generators can be juxtaposed at the same time.
  • Prevent self-excitation resonance phenomenon that may occur in the long line of the generator.
  • When the neutral point of the reactor is used to pass the small reactance grounding device, the small reactor can also be used to compensate the phase and phase capacitance of the line to accelerate the automatic extinguishing of the submerged current, which is convenient to adopt.